EQ Tank
Stabilize your process flows
Improve your chemical dosing control and overall performance
Configure your system with mixing, aeration, level control, and integrated pumping to match your application
EQ Tank Configurator
Part #
TNK-[EQ]-[SHAPE]-[MAT]-[VOL]-[MIX]-[CTRL]
1
Tank Shape
▶
Select the tank geometry best suited to your site layout and hydraulic requirements. Vertical cylindrical tanks are the most common for EQ service. Rectangular tanks are preferred where headroom is limited.
CYL-V Standard
Vertical Cylindrical
Most common for EQ service; efficient mixing; smaller footprint
RECT
Rectangular
Preferred where headroom is limited; fits existing concrete structures
CYL-H
Horizontal Cylindrical
Low-profile; above or below grade; agricultural and transportation applications
CONE
Cone Bottom
Complete drainage; settling and solids-bearing streams requiring periodic cleanout
OT
Open Top
Open-top EQ basin; concrete-integrated or freestanding steel; aeration access
CUST
Custom Shape
Non-standard geometry; provide site constraints for engineering review
2
Material of Construction
▶
Select tank material based on wastewater chemistry, temperature, and regulatory requirements. 304SS is the standard for most industrial EQ tanks. Carbon steel is cost-effective for non-corrosive streams.
CS
Carbon Steel — Epoxy Lined
Most economical; internal epoxy lining for corrosion resistance; indoor or sheltered service
304SS Standard
304 Stainless Steel
General-purpose stainless; food, beverage, and industrial wastewater; excellent cleanability
316SS
316 Stainless Steel
Chloride-bearing, acidic, or high-temperature streams; pharmaceutical and chemical service
CONC
Concrete
Large civil-integrated basins; coating liner applied; site-poured or precast
PP
Polypropylene
Excellent chemical resistance; -40°F to 200°F; plating and aggressive chemical environments
HDPE
HDPE
Below-grade or buried installations; impact and UV resistant; chemical resistant
3
Volume
▶
Select nominal EQ tank volume. EQ tanks are typically sized for 2–8 hours of average daily flow to buffer batch production and sanitation shift surges. Tenco Hydro can provide sizing assistance based on your flow profile.
G5000
~5,000 Gallons
Small facility; flow <25 GPM average; ~2–4 hrs detention
G10000
~10,000 Gallons
Small-medium facility; 25–50 GPM average
G25000
~25,000 Gallons
Medium facility; 50–100 GPM average; standard for food/bev
G50000
~50,000 Gallons
Large facility; 100–200 GPM average
G100000
~100,000 Gallons
Very large facility or extended buffer; 200–400 GPM average
GXXX
Custom Volume
Replace XXX with volume in gallons (e.g. G75000 = 75,000 gal). Range: 500–1,000,000 gal.
4
Mixing / Aeration
▶
Select the mixing or aeration method to prevent solids settling and maintain homogeneous conditions in the EQ tank. Mechanical mixing is standard for most industrial EQ tanks. Aeration is used when biological activity or odor control is beneficial.
MXR Standard
Mechanical Mixer
Top-entry or submersible mixer; prevents solids settling; VFD speed control available
AIR-D
Diffused Air Aeration
Fine or coarse bubble diffusers; mixing + DO addition; odor suppression for FOG-bearing streams
AIR-S
Surface Aerator
Floating or fixed surface aerator; open-top basins; high oxygen transfer efficiency
RECIRC
Recirculation Pump Mixing
In-tank recirculation via pump and nozzle; no separate mixer required; low maintenance
NONE
No Mixing
Quiescent settling tank; primary settling or low-solids equalization only
5
Controls
▶
Select the controls tier for the EQ tank mixer, pump, level monitoring, and integration with upstream/downstream equipment.
C0
No Controls
Motors and devices supplied for field wiring only. All starters and controls by others.
C1
Basic Level + Motor Starter
Float or probe level switch with high-level alarm. Local motor starter for mixer. Manual pump control.
C2 Standard
Level Control + Auto Pump
Radar level transmitter with 4–20 mA output. Automated feed pump start/stop based on level. High-level alarm output.
C3
PLC + Full Automation
PLC-based with HMI. Level-paced feed to downstream DAF or treatment. pH monitoring. Alarm history. SCADA/DCS interface available.
6
Accessories & Add-Ons (Optional)
▶
Select optional accessories. Multiple selections allowed.
Instrumentation
LIT
Radar Level Transmitter
Continuous 4–20 mA level output with high-level switch; standard for C2+ systems
pH-P
pH Probe + Transmitter
Submersible pH electrode; 4–20 mA output; upstream pH monitoring before treatment
FI
Inlet Flow Meter
Mag meter or clamp-on ultrasonic on EQ tank inlet for flow totalization and control
TEMP
Temperature Sensor
RTD or thermocouple with transmitter; hot process streams or freeze protection monitoring
Tank Features
HATCH
Manway / Access Hatch
Bolted or hinged manway for interior inspection and cleanout access
INSUL
Tank Insulation
Foam or fiberglass insulation jacket; cold climate temperature retention
HEAT
Tank Heater / Heat Trace
Immersion heater or external heat trace; freeze protection or process temperature maintenance
COVER
Cover / Odor Control
Fixed or floating cover for odor containment; venting to carbon filter or treatment
OVF
Overflow / Emergency Weir
Gravity overflow weir or pipe at high-high level; prevents tank overfill
AP
Access Platform
OSHA-compliant platform, ladder, and handrails for safe tank access
Services
Install
Installation Services
Tenco Hydro field installation and commissioning
TURNKEY
Turnkey Wastewater Room
Complete room design, supply, and installation including all equipment
Configuration Summary
Tank Shape—
Material—
Volume—
Mixing/Aeration—
Controls—
AccessoriesNone
0 of 5 configured
Part Number Format
TNKSeries prefix
EQApplication — Equalization
[SHAPE]Tank geometry
[MAT]Material
[VOL]Volume in gallons
[MIX]Mixing/aeration type
[CTRL]Controls tier
+[ACC]Accessories (optional)
Ready to Quote?
Send your completed part number to Tenco Hydro. Budgetary pricing within 2–3 business days.
Request a Quote
Engineers Respond Within 2 Business Hours
Complete the configurator above to auto-fill your part number, then describe your application below.
📞
Phone
📍
Location
720 N Heartland Dr Unit K
Sugar Grove, IL 60554
Sugar Grove, IL 60554
🕐
Hours
Mon–Fri, 7:00 AM – 5:00 PM CT
🏭
Specialties
304/316SS welding · ASME stamping
PE stamps all 50 states · In-house fabrication
PE stamps all 50 states · In-house fabrication
✅
Request Received!
A Tenco Hydro engineer will follow up within 2 business hours.
Questions? Call 708-387-0700.